############ SUMMARY ############
To check firmware, boot and Config register:
show version ==> Configuration register 0xF (for 2960x)
show boot ==> boot control
show switch ==> stack status.
dir flash: ==> flash disk firmware and free space control.
Upgrade firmware and web management:
archive download-sw /overwrite scp://<username>:<password>@10.10.10.100/c2960x-universalk9-tar.152-7.E6.tar
or
archive download-sw /overwrite tftp://10.10.10.100/c2960x-universalk9-tar.152-7.E6.tar
After upgrade check installed firmware:
dir flash:
hash control:
verify /md5 flash:c2960x-universalk9-mz.152-7.E6/c2960x-universalk9-mz.152-7.E6.bin
Boot control:
show boot
Reload switch stack. 3 unit stack reload takes 10-15 minutes.
Check loaded firmware:
show version
############ PRE FIRMWARE UPGRADE ############
S5#show switch
Switch/Stack Mac Address : c472.xxxx.aaaa
H/W Current
Switch# Role Mac Address Priority Version State
———————————————————-
*1 Master c472.xxxx.aaaa 15 4 Ready
2 Member c472.xxxx.bbbb 10 4 Ready
3 Member 689c.xxxx.cccc 1 4 Ready
Stack Port Status Neighbors
Switch# Port 1 Port 2 Port 1 Port 2
——————————————————–
1 Ok Ok 2 3
2 Ok Ok 3 1
3 Ok Ok 1 2